Cephalomentric AtoZ V.16
Effective for raising patient's motivation during the first examination.
Digital X-ray support, available immediately after installation.
Useful for making decision on tooth extraction.
Can be used as a demonstration tool during consultation.
Good for prediction of teeth growth and simulation of treatment results.
Search engine for similar cases.
Due to database feature can be accessed from each chair.
Network support, data sharing
Can be used on Windows and Macintosh.
Easy to use  Orthodontics Analysis simolation software
1. JPEG image database function
2. Quick Ceph data now can be imported!
3. Additional view layout
4. About reference folder
5. Setting a print direction
6. Two new functions were added to tool window
7. Importing a set of color images
8. Readjust an image
9. Thumbnail input.
10. Treatment simulation supports Occlusal plane.
11. Minimize a treatment dialogue.
12. Renew icon data. MacOS 10.6
13. X-rays and Photo input the trace of the soft tissue separately.
14. It corresponds to Mac OS 10.7 Lion.
15. It corresponds to touch-panel monitor.
16. Analytic change is possible in a tool window.
17. Tool window is folded up.
18. X-RAY image tool / Photo image tool
19. New thumbnail input window
20. The data picture inspection function of AtoZ
21. Diagnosis window dialog
22. It was made easy to input on FH standard.
23. 3D model
24. Change color
25. Slice
26. Input frontal line with point mode
27. About the format of the numerical value of trace
28. Show only trace by Lateral(Color).
29. JPEG image output
30. About the format of the numerical value of trace
31. Printing of panorama X rays
32. view layout
33. Color Gradation Display on Polygon
34. Mac OS 10.9 Mavericks and Windows8 Support
35. Trace Color Setting.
36. Co-Cr Conversion
37. A4、A3 Print Format
38. Smooth Trace Line
39. Trace Lien width
40. Improvement of AtoZ data Browser.
41. Improvement of JPEG Browser
42. Enlarge/Shrink the window of Polygon and Superimposition
43. 17 Landmarks Input
44. Cross on the Center of “Superimpose X-ray”
45. Multiple Facial Diagram Display within the Folder
Volume Rendering:

CephaloMetrics AtoZ provides 2D orthodontic diagnosis and 3D dental model viewer now. AtoZ supports DICOM data from CT scans for 3D volume rendering in the ver.16.

Ariway:
Airway is inputted on a point, and it is displayed by 3D. Information, including volume etc., is also displayed on the upper right.

Super impostion:
Two scans can be superimposed.

Section:

Cephalo:
A Cephalo picture can be outputted from 3D.

Preset:
Click a button and a volume view changes.
Original preset is customizable.

Trace and a numerical value are edited by illustrator:
A window is copied and it pastes on illustrator. Line and a numerical value can be edited.
(Function from Ver.16.01)
Database Copying Crown
Full Crown Reduce Waxup Bridges Frakwork
Autho Adaptation Bridge Framwork Inlay Bridge
IHow to import x-ray images

1. Import from x-ray films through EPSON scanner with transparency unit for film scanning.
2. Import from Imaging Plate. (JPEG, DICOM, TIFF, and BMP are available.)
3. Import image files from CCD digital x-ray. Import image data exported with x-ray devices of each manufacture. Besides JPEG, DICOM, TIFF, and BMP have been added as image format.
4. Import tracing written with WACOM tablet.
Image Plate
Take the image with image plate instead of x-ray film on x-ray devices you have used in your clinic, and then import it as digital data with a special scanner. Save a file in JPEG and DICOM image format, and import it into AtoZ.
CCD Digital X-ray
AtoZ is available to import x-ray images taken with CCD digital x-ray devices made by any manufactures.
Import DICOM Files
DICOM (Digital Imaging and Communications in Medicine) is a standard for digital medical images and network communication protocol. A DICOM format includes patient information such as name, date of birth, and sex, and AtoZ can load these information as needed.
Import Color Photo

AtoZ can import high resolution slide with a scanner with transparency in EPSON, and also import images taken in digital camera easily. High resolution images in image processing software such as Photoshop can be copied temporally and be pasted on AtoZ. Images can be edited by a trimming frame, and right/left inversion, horizontal/vertical inversion, or clockwise/counterclockwise rotation are available.

Thumbnail Input

JPEG images taken with digital camera can be imported by dragging and dropping with checking images in thumbnail view. If x-ray images are saved as JPEG files, they are used as well.
After choosing image folder, drag and drop image files from the right image list to the left place corresponding to an image. The image becomes translucent when moving it to know what image is selected.
Informed consent documents

For orthodontic consultation, make an informed consent document easily through only taking intraoral images without x-ray. Import intraoral images and print it out, and then use for explanation to a patient to give the document and get access to the start of treatment.

"Smile" Function

Using the lasso tool, it is available to simulate the patient smile with brackets before treatment and create the image how the patient will change. In addition, you can explain the difference between metal brackets and ceramic brackets in anterior teeth before starting treatment.
Input Straight Line and Angle

You can write straight lines and angles in the images. You can explain patient writing additional lines and angles on tracing images after analysis. This function is more effective to make it clear for measurement and presentation.
Image enhancement

X-ray image can be more clear with image processing. Before inputting point, teeth root and the part of unclear soft-tissue line are enclosed with a frame tool, and then the image is enhanced partly.

Input Analysis Point

Image processing makes the x-ray image clear and you can plot points directly on the computer screen.
Point input is conducted listening computer voice and confirming the position of points with a guidance window. In lateral analysis, 32 points and 4 lines should be inputted.You can choose to use or not 32th point, which is PAC.

Template Input

Not only conventional point input, template input is available. Input 3 points: Porion, Orbitale, and Gnathion, or 2 points: Sella and Nasion, and then all points and tracing are displayed. Input each point drag with mouse. After inputting points, start line input.
Analysis

Lateral analysis is set by default, but there are up to 16 other models such as Ricketts, Steiner, McNamara, Downs&Kim, Jarabak, angle analysis, distance analysis, soft tissue analysis, Bimler analysis, Tweed, Roth etc that can be applied. The image can be rotated in right/left for Bimler analysis. Original analysis can be defined.
There are Rickets analysis and symmetry analysis in frontal analysis. In addition, Submento vertex analysis is supported.

User Analysis Definition

Up to 60 points can be defined as additional definition in both lateral analysis and frontal analysis. 60 items of measurement item, standard value, standard deviation, and lines can be used freely as user definition.
Display Measurement Value

The display of standard value can be changed. All contents on the screen can be displayed in the analysis.
Facial Diagram

Superimpose the standard values and SN-FH plane, and display soft-tissue on facial diagram.
The standard value can be changed according to the method of the university. Measurements in angle are also displayed.
Polygon

Display polygon of analysis result. Choose the standard value for each stage in Downs-North Western analysis and Liner analysis to display polygon.
Superimpose

In superimposition mode, you can select the position of superimposition such as SN@S and FH@S, and the position is changed immediately. Drag the image with mouse to rotate and move the superimposed image freely.
Orthodontic and Oral Surgery Simulation

Orthodontic and oral surgery simulation are available in lateral and frontal. Using oral surgery simulation on lateral, you can make four places of lower jawbone and one place of upper jawbone cut. In addition, enter numeric value for treatment simulation on a treatment dialog. User definition is available for the movement of soft-tissue in orthodontic treatment simulation. Morphing of color photo provides smooth image simulation by sophisticated mapping technique.
A Variety of View Format

According to a variety of view format, you can provide a presentation of similar cases at initial consultation and print out image files in before-and-after treatment. Display the comparison of before-and-after simulation.
Select a format in a view palette. As well as other applications, copy and paste text and image in Edit menu. (Install enough memories on the computer.)
Use AtoZ on Local Network

Save the patient data on the server, and access the data to read and write from each client. Save the data on the specified folder. Register the saving folder by default.

Use AtoZ Data on Both Macintosh and Windows

Share all AtoZ patient data created on Windows and Mac without any data conversion. In local network, even if Mac and Windows are mixed, the AtoZ data can be used.
How to Use AtoZ Database

AtoZ image data and patient data file on the server can be displayed immediately. Search and display the patient data by specifying name and patient number. Define three types of arrangement of images. AtoZ is in the least inferior to other database software in displaying speed.
Image browser

JPEG, DICOM, and TIFF image format is available for browsing. On the left side, patient folders are displayed while the patient data in the folder is displayed on the right side. Double-click image to enlarge it.
Enter patient name of the folder in search box on the top right for narrowing retrieval. It also sorts folders by created data.
About resolution of analog X-ray image

When importing an X-ray film, the default resolution settings may vary from version to version. It is recommended to print out a trace on a regular basis and check the resolution by imposing.


About reading Quick Ceph data on Macintosh OS X

Quick Ceph data can not be imported on Macintosh versions of OS newer than 10.4. Please, use Macintosh versions of OS later than 10.3.

Windows computers

    Intel Core 2 Duo
    RAM 4GB+ recommended
    HD 500GB+ recommended
    DVD±RW/±R, CD-RW
    Windows XP, 7
    17inch TFT monitor SXGA+ recommended
    1280×1024+ recommended
    •can be used on notebook


Macintosh computers

    Mac mini, iMac, Mac Pro
    RAM 4GB+ recommended
    HD 512GB+ recommended
    DVD±RW/±R, CD-RW
    Mac OS X10.5 - OS 10.8 Snow Leopard
    17 inch TFT monitor SXGA + recommended
    1280×1024+ recommended
    •can be used on MacBook, MacBook Pro notebooks


Scanner



    EPSON Perfection V750-M Pro Scanner
    6400dpi, dual lens system, A4 format supported, high-definition
    • In case a digital X-ray equipment is used, there is no need for transparent scanner
    Our software supports IP Plate (Densply, Combi X) and CCD digital X-ray images (JPEG, DICOM formats) made with the equipment from such manufacturers as "Morita", Asahi Roentgen", "Trophypan" etc.


Digital camera

    Digital cameras from makers such as OLYMPUS, Nikon etc. can be used as well
    Format which supports: JPEG, TIFF, BMP, PICT, DICOM


Printer


    EPSON Artisan 50 Ink Jet Printer etc

iTecGuide
CRYSTAL CORRECT
Back
Next